ANT

Compact weighing indicator

A compact weighing indicator for a range of industrial weighing applications.

Process and measurement

ANT, Compact weighing indicator

Drag to rotate; pinch or use the mouse wheel to zoom; double-tap resets the view. On the keyboard, arrow keys rotate, + and − zoom, 0 resets.

scale, multi-material
1
Modbus RTU
RS485
internal counter resolution
20 bit
mm
70 × 91 × 58

ANT is a single-scale weighing and dosing control unit with multi-material filling. It was designed for concrete plant automation, and its compact build suits other industrial weighing jobs as well.

It communicates over RS485 Modbus RTU. Calibration is done with the device keys or from BetonicTCP.

In 5-scale plants, ANT is added next to the HAWK automation set to weigh the fifth scale: HAWK + ANT 5-scale set.

Technical specifications

Weighing

Scale
1 scale, multi-material filling
Input type
Load cell or pulse meter
Load cell excitation
5 V DC
Load cell input resistance
350 Ω
Internal counter resolution
20 bit

Inputs and outputs

I/O
2 digital inputs, 2 digital outputs (fast and fine filling)

Communication

Communication
RS485 Modbus RTU
Baud rate
1200 - 115200 bps

Electrical

Supply voltage
12-24 V DC (24 V DC recommended)

Mechanical and environment

Dimensions
70 × 91 × 58 mm
Operating temperature
-20 °C to +50 °C

Source: ANT User Manual (Turkish, firmware VR 52)

For demonstration only

Put a load on the scale,
watch the reading.

Drag the test weights onto the platform or tap to place them. The reading swings until the load settles; once it holds, the stable lamp lights up. Try the zero and tare keys as well.

For demonstration only. The weights and readings are examples; this is not an exact copy of the HAWK or ANT display. Capacity and division are set for your scale.

Weighing indicatorExample
Total (gross)
0 kg
Tare
0 kg
Net
0 kg
Scale platform
Test weights

Drag a weight onto the platform or tap it; tap again to put it back.

Troubleshooting ANT

Troubleshooting steps from the manual. Pick the problem to see the steps.

Full troubleshooting guide
Weighing is wrong after C 01, C 02 or C 03 was changedANTHAWK

Possible cause

Scale capacity and calibration are set by C 01 (division value), C 02 (number of divisions) and C 03 (decimals); changing them breaks the calibration.

Steps to solve it

  1. Restore the old values or recalibrate for the new values.
  2. Calibrate with reference (test) weights of known mass.

Note In case of a fault, the indicator or load cells can be tested in the IC SAYAÇ (internal counter) menu.

Request a quote for this product.

Tell us briefly about your plant or weighbridge and we will reply with a suitable configuration.